Model   SonomaTesting ST53123A Agilent 53123A Pendulum CNT-90
 

$1,750.00

add_to_cart.gif  view_cart.gif

   
   
   
List Price  USD 1,750.00   USD 5,664.00   USD 2,775.00 
Range Frequency 1mHz to 400MHz ( upto 6 GHz on Channel 3 ) 0.1 Hz to 225 MHz (5 GHz optional) 1mHz to 300MHz ( upto 3 GHz Ch 3 - Option )
Period 2.5 ns to 1000secs. 4.44 ns to 10sec 3.3 ns to 1000secs.
Ch 1 & 2 Input Characteristics Impedance 1 MΩor 50Ω 1 MΩor 50Ω 1 MΩor 50Ω
Capacitance (1MΩ ) 24pF 30pF 20 pF
Coupling AC / DC AC / DC AC / DC
Low Pass Filter 100 KHz, -20 dB, @ > 1 MHz (Switchable) 100 KHz, -20 dB, @ > 1 MHz (Switchable) Nominal 100 KHz, R-C Type
Display Resolution Frequency   12 Digits/ sec. 12 Digits/ secs 12 Digits/ sec.
Voltage Range and Sensitivity 1mHz - 225MHz 20 mVRMS ± 5VAC + DC 40 mVRMS ± 5VAC + DC 15 mVRMS ± 5VAC
225MHz - 400MHz 30 mVRMS ± 5VAC + DC   25 mVRMS ± 5VAC
Frequency Ratio Result Range 10e-10 to 10e+11 10e-10 to 10e+11 10e-9 to 10e+11
Resolution 11 Digits /sec 8 Digits / sec not specified
Time Interval Result Range -1.5ns to 10e+5 secs. -1.5ns to 10e+5 secs. 0 to 10e+6 secs.
Period 40ps 150ps 100ps (50ps for CNT-91)
Phase -180o to +360o -180o to +360o -180o to +360o
Duty Cycle (set @ 50%) Result Range 0 to 1 0 to 1 0 to 1
Min. Pulse Width > 1ns > 4ns 1.6ns
Rise / Fall Time 1.5ns to 10e+5sec 5ns to 10e+5sec 1.5ns to 10e+6sec
Pulse Width 1.5ns to 10e+5sec 5ns to 10e+5sec 2.3ns to not specified Max
Totalize 0 to 10e+15 ( ±1 count Systematic Uncertainty) 0 to 10e+15 ( ±1 count Systematic Uncertainty) 0 to 10e+10 ( CNT-91 only)
Trigger Level Range + 5.125V + 5.125V not specified
Resolution 2.5mV 5mV 3mV
Peak Volt Mode (1Vpp, 50 Ω, ATT Off) DC Signal 15mV + 2% of V  25mV + 2% of V  
100Hz - 10KHz 15mV + 2% of V  25mV + 10% of V  
10KHz - 5MHz 15mV + 3.5% of V  25mV + 10% of V  
5MHz - 80MHz 15mV + 6% of V  25mV + 10% of V (upto 30MHz only)  
80MHz - 300MHz 15mV + 13% of V    
Temperature Stability (0 to 50oC, Ref. to 25oC) < 1ppm < 5ppm < 10 ppm
Aging Rate < 2 ppm ( per YEAR) < 0.3 ppm (per MONTH) < 5 ppm ( per YEAR)
Calibration (Standard) Electronic Manual not specified
Operating Environment   0o to 55oC 0o to 50oC 0o to 50oC
I/O Interface RS-232 No Yes (Talk Only) No
USB Yes No Yes
GPIB Option Yes Yes
Ethernet Yes No No
Software Included not specified not specified
Programming Language   SCPI-1992.0, IEEE488 SCPI-1992.0 SCPI-1999, IEEE488
Web Server Capability Yes (Default IP: 192.168.0.247) No No
Front End Isolation   Yes No not specified
Power 50 / 60 Hz 100 to 240 V 100 to 240 V ± 10% 90 to 265 V
400 Hz 100 to 127 V  100 to 120 V ± 10%  90 to 265 V
Requirements 50 VA Max 170 VA Max < 40 W
Built in Channel 3 Yes (Standard) No (Optional) No (Optional)
Channel 3 Power Range & Sensitivity (Sinusoid) 375 MHz to 500 MHz - 16 dBm to + 15 dBm not specified (optional feature) not specified (Optional)
500 MHz to 1 GHz - 20 dBm to + 15 dBm
1 GHz to 2 GHz - 23 dBm to + 15 dBm
2 GHz to 4 GHz - 25 dBm to + 15 dBm
4 GHz to 5 GHz - 23 dBm to + 15 dBm
5 GHz to 5.5 GHz - 20 dBm to + 15 dBm
5.5 GHz to 6 GHz - 17 dBm to + 15 dBm
Damage Level DC - 400MHz, 50Ω 12 VRMS 5 VRMS 12 VRMS
0 to 3.5 KHz, 1MΩ 350 VDC + ACPK 350 VDC + ACPK 350 VDC + ACPK Lineary derated to  12 VRMS
3.5KHz to 100KHz, 1MΩ 350 VDC + ACPK Lineary derated to  12 VRMS 350 VDC + ACPK Lineary derated to  5 VRMS
100KHz to 400KHz, 1MΩ 12 VRMS 5 VRMS (to 225 MHz only)
Weight (kg)       2.7
Dimension (WHD in Inches)       8.25 x 3.6 x 15.6
Specifications and pricing subject to change. Information taken from Agilent and Pendulum Websites on December 1, 2008